Schneider Electric
TeSys GV3 Circuit breaker-thermal-magnetic - 23…32A - EverLink BTR connectors - GV3P32
Out of stock
SKU
GV3P32
Details
TeSys GV motor circuit breaker, 3 poles (3P), 32A/690V, for 3-phase motor applications 15kW@400V.
It provides a thermal-magnetic protection with a thermal setting range 23-32A, magnetic tripping at 14xIn, high breaking capacity Icu 100kA@400V.
Connection by Everlink BTR screw terminals.
Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3.
Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
More Information
Attribute | Value |
---|---|
SKU | GV3P32 |
product certifications | EAC, CCC, LROS (Lloyds register of shipping), BV, CSA, UL, ATEX, IECEE CB Scheme, DNV-GL, ABS |
ambient air temperature for storage | -40-80 °C |
ambient air temperature for operation | -20-60 °C |
magnetic tripping current | 448-448 A |
range of product | TeSys GV3 |
operating position | any position |
product or component type | motor circuit breaker |
net weight | 0.96 kg |
standards | EN/IEC 60947-2, UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1 |
mechanical durability | 50000 cycles |
device short name | GV3P |
breaking capacity | 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2, 12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
trip unit technology | thermal-magnetic |
range | TeSys GV |
IK degree of protection | IK09 |
trip unit rating | 23-32 A |
product name | TeSys GV3 |
power dissipation per pole | 8 W |
[Ith] conventional free air thermal current | 32 A conforming to IEC 60947-4-1 |
direct connector | without |
network frequency | 50/60 Hz conforming to IEC 60947-4-1 |
height | 132 mm |
compatibility code | GV3P |
width | 55 mm |
depth | 136 mm |
operating altitude | 3000 m |
IP degree of protection | IP20 conforming to IEC 60529 |
[In] rated current | 32 A |
network type | AC |
poles description | 3P |
tightening torque | 5 N.m on EverLink BTR screw connectors for cable 25-25 mm², 8 N.m on EverLink BTR screw connectors for cable 35-35 mm² |
electrical durability | 50000 cycles for AC-3 at 440 V In |
device application | motor |
control type | rotary knob |
[Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
fixing mode | 35 mm symmetrical DIN rail: clipped, panel: screwed (with 3 x M4 screws) |
utilisation category | category A conforming to IEC 60947-2, AC-3 conforming to IEC 60947-4-1 |
[Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
suitability for isolation | yes conforming to IEC 60947-1 |
maximum operating rate | 25 cyc/h |
protective treatment | TH |
fire resistance | 960 °C conforming to IEC 60695-2-1 |
motor power kW | 15-15 kW at 400/415 V AC 50/60 Hz, 18.5-18.5 kW at 500 V AC 50/60 Hz, 22-22 kW at 690 V AC 50/60 Hz |
phase failure sensitivity | yes conforming to IEC 60947-4-1 |
rated duty | continuous conforming to IEC 60947-4-1 |
[Ics] rated service short-circuit breaking capacity | 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2, 50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Technical Documents