TeSys GV motor circuit breaker, 3 poles (3P), 3.5A/690V, for protection of 3-phase motors 0.55-1.5kW@400V.

Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals.

Thermal protection adjustable by dials with a setting current Ir in range 1.4-3.5A and a selectable tripping class 10 or 20, magnetic protection at 17 In.

Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start.

It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX).

It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation.

Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).

More Information
More Information
Attribute Value
SKU GV4PEM03N
product certifications EAC, CCC, IEC, CSA, UL, ATEX, EU-RO MR
ambient air temperature for storage -50-85 °C
pollution degree 3 conforming to IEC 60947-1
ambient air temperature for operation -25-70 °C
quality labels CE
magnetic tripping current 59-59 A
rotary handle padlocking with a lock accessory
product or component type motor circuit breaker
net weight 1.45 kg
mounting mode by screws, by clips
standards EN/IEC 60947-2, UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1
tropicalisation 2 conforming to IEC 68-2
mechanical durability 40000 cycles
device short name GV4PEM
breaking capacity Icu 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2, Icu 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2, Icu 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, Icu 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2, 65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947, 65 kA at 240 V AC 50/60 Hz conforming to UL 60947, 35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947, Icu 8 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2, Icu 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2, 18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
trip unit technology thermal-magnetic, electronic
range TeSys GV
wire stripping length 20 mm
IK degree of protection IK07 conforming to IEC 62262
[Ics] rated service breaking capacity 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2, 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2, 2 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
product name TeSys GV4
mechanical robustness vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6, vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6, shocks: 15 gn 11 ms conforming to IEC 60068-2-27
connections - terminals top 1 EverLink BTR screw connectors wire size 1.5-70 mm², solid, top 1 EverLink BTR screw connectors wire size 1.5-50 mm², flexible, bottom 1 EverLink BTR screw connectors wire size 2.5-95 mm², solid, bottom 1 EverLink BTR screw connectors wire size 2.5-70 mm², flexible
height 155 mm
mounting support plate, 35 mm symmetrical DIN rail, 75 mm symmetrical DIN rail
width 81 mm
depth 116 mm
operating altitude 0...2000 m without derating, 2000...5000 m with derating
IP degree of protection IP40 front face conforming to IEC 60529
[In] rated current 3.5 A
poles description 3P
colour grey (RAL 7016)
tightening torque 9-9 N.m for 16-95 mm², 5-5 N.m for 1.5-10 mm²
electrical durability 40000 cycles for AC-3 at 440 V In/2, 40000 cycles for AC-3 at 440 V In
device application motor protection
control type toggle
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
local signalling flashing LED (green) for ready, LED (red) for alarm (T° >95%), green indicator for presence of auxiliary contacts
protection type overload, phase loss, ground fault protection, jam, short-circuit, short time short-circuit protection, locked rotor, phase unbalance, long start
utilisation category category A
connection pitch 27 mm
[Ui] rated insulation voltage 800 V conforming to IEC 60947-2
suitability for isolation yes conforming to IEC 60947-1
motor power kW 1.5-1.5 kW at 400...415 V AC 50/60 Hz, 0.55-0.55 kW at 400...415 V AC 50/60 Hz, 0.75-0.75 kW at 400...415 V AC 50/60 Hz, 0.75-0.75 kW at 500 V AC 50/60 Hz, 1.1-1.1 kW at 500 V AC 50/60 Hz, 1.1-1.1 kW at 660...690 V AC 50/60 Hz, 1.5-1.5 kW at 660...690 V AC 50/60 Hz, 1.5-1.5 kW at 500 V AC 50/60 Hz, 2.2-2.2 kW at 660...690 V AC 50/60 Hz, 1.1-1.1 kW at 400...415 V AC 50/60 Hz
thermal protection adjustment range 1.4-3.5 A
communication port protocol NFC
phase failure sensitivity yes conforming to IEC 60947-4-1
motor tripping class 10, 20
number of slots 1 slot(s) for alarm switch for fault signalling contact, plug-in, 1 slot(s) for voltage release for electrical remote tripping, plug-in, 1 slot(s) for auxiliary switch for open/close contact, plug-in
[Isd] short-time pick-up adjustment range 5...13 x Ir