TeSys GV5 Motor circuit breaker, 3P, 150A, Icu 70kA, thermal magnetic - GV5P150H
TeSys GV motor circuit breaker, 3 poles (3P), 150A/690V, for protection of 3-phase motors 55-75kW@400V.
It provides thermal magnetic protection and additional protections, breaking capacity Icu 70kA, start-stop control by rotary handle, connection for bars or cables with lugs (direct connection of cables with additional connectors).
Thermal protection adjustable by dials with a setting current Ir in range 70-150A and a selectable tripping class 5, 10 or 20, magnetic protection at 15 In.
Additional protections with fixed pick-up include short time delay protection Isd at 13 Ir, phase unbalance and loss protection.
It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX).
Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Attribute | Value |
---|---|
SKU | GV5P150H |
product certifications | IECEE CB Scheme, EAC (pending) |
ambient air temperature for storage | -55-85 °C |
overvoltage category | III |
pollution degree | 3 |
ambient air temperature for operation | -25-70 °C |
magnetic tripping current | 2250-2250 A |
range of product | TeSys GV5 |
product or component type | motor circuit breaker |
net weight | 2.4 kg |
standards | EN/IEC 60947-2, EN/IEC 60947-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1 |
mechanical durability | 40000 cycles |
device short name | GV5P |
breaking capacity | 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2, 70 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
trip unit technology | electronic |
range | TeSys GV |
IK degree of protection | IK07 conforming to IEC 62262 |
trip unit name | Micrologic 2.2 M |
trip unit rating | 150-150 A |
breaking capacity code | H 70 kA |
product name | TeSys GV5 |
mechanical robustness | vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6, vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6 |
power dissipation per pole | 9.2 W |
mounting position | horizontal and vertical |
connections - terminals | power circuit: bars - busbar cross section: 25 x 6 mm, power circuit: lugs - external diameter: 25 mm |
height | 161 mm |
width | 105 mm |
depth | 155 mm |
operating altitude | 0...2000 m without derating |
IP degree of protection | IP40 conforming to IEC 60529 |
[In] rated current | 150 A at 65 °C |
poles description | 3P |
colour | anthracite (RAL 7016) |
tightening torque | 15 N.m screw : M8 |
electrical durability | 20000 cycles for AC-3 at 400/415 V In |
device application | motor protection |
control type | direct rotary handle |
[Ue] rated operational voltage | 690 V AC 50/60 Hz |
local signalling | LED ready, LED 95 % Ith |
fixing mode | by screws |
protection type | short-circuit protection, overload protection, phase loss, phase unbalance, instantaneous short-circuit protection |
utilisation category | category A conforming to IEC 60947-2 |
connection pitch | 35 mm without spreaders |
[Ui] rated insulation voltage | 800 V AC 50/60 Hz conforming to IEC 60947-2 |
suitability for isolation | yes conforming to EN/IEC 60947-2 |
maximum operating rate | 25 cyc/h |
protective treatment | TC |
fire resistance | 960 °C conforming to IEC 60695-2-1 |
motor power kW | 55-75 kW at 400/415 V AC 50/60 Hz, 75-90 kW at 500 V AC 50/60 Hz, 90-110 kW at 660/690 V AC 50/60 Hz |
thermal protection adjustment range | 70-150 A adjustable 9 settings |
phase failure sensitivity | yes conforming to IEC 60947-4-1 |
[Isd] short-time pick-up adjustment range | 5...13 x Ir adjustable 9 settings |
rated duty | continuous |
thermal overload class | class 5 conforming to IEC 60947-4-1, class 10 conforming to IEC 60947-4-1, class 20 conforming to IEC 60947-4-1 |
[Ics] rated service short-circuit breaking capacity | 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |