TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 220...230 V AC coil - LC1K0601M7
            Out of stock
        
    
            SKU
        
LC1K0601M7
                        Details
                    
                    
TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2.2kW@400V).
It provides a 220V 50/60Hz AC coil, 1NC built-in auxiliary contact, connection by screw clamp terminals.
For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications.
Very compact (45mm width), DIN-rail mounting or screw fixing.
Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
                        More Information
                    
                        | Attribute | Value | 
|---|---|
| SKU | LC1K0601M7 | 
| product certifications | CSA, UL | 
| ambient air temperature for storage | -50-80 °C | 
| overvoltage category | III | 
| [Icw] rated short-time withstand current | 90 A 50 °C - 1 s for power circuit, 85 A 50 °C - 5 s for power circuit, 80 A 50 °C - 10 s for power circuit, 60 A 50 °C - 30 s for power circuit, 45 A 50 °C - 1 min for power circuit, 40 A 50 °C - 3 min for power circuit, 20 A 50 °C - >= 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit | 
| range of product | TeSys K | 
| product or component type | Kontaktor | 
| net weight | 0.18 kg | 
| standards | BS 5424, IEC 60947, VDE 0660, NF C 63-110 | 
| mechanical durability | 10 Mcycles | 
| device short name | LC1K | 
| range | TeSys F | 
| average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit | 
| [Ie] rated operational current | 6 A at <= 440 V AC AC-3 for power circuit | 
| [Uc] control circuit voltage | 220...230 V AC 50/60 Hz | 
| [Uimp] rated impulse withstand voltage | 8 kV | 
| product name | TeSys K | 
| minimum switching current | 5 mA for signalling circuit | 
| mechanical robustness | vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6, shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 | 
| [Ith] conventional free air thermal current | 20 A (at 50 °C) for power circuit, 10 A (at 50 °C) for signalling circuit | 
| control circuit type | AC at 50/60 Hz | 
| safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | 
| contactor application | motor control | 
| contactor coil voltage | 220 V AC standard, 230 V AC standard | 
| insulation resistance | > 10 MOhm for signalling circuit | 
| rated breaking capacity | 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947, 110 A at 415 V conforming to IEC 60947, 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947 | 
| Irms rated making capacity | 110 A AC for signalling circuit conforming to IEC 60947, 110 A AC for power circuit conforming to NF C 63-110, 110 A AC for power circuit conforming to IEC 60947 | 
| power range | 1.1-2 kW at 200-240 V 3 phases, 2.2-3 kW at 380-440 V 3 phases, 2.2-3 kW at 480-500 V 3 phases, 1.1-2 kW at 380-440 V 3 phases, 1.1-2 kW at 480-500 V 3 phases, 0-0.5 kW at 200-240 V 3 phases, 0.55-1 kW at 200-240 V 3 phases, 0-0.5 kW at 380-440 V 3 phases, 0.55-1 kW at 380-440 V 3 phases, 0-0.5 kW at 480-500 V 3 phases, 0.55-1 kW at 480-500 V 3 phases | 
| pole contact composition | 3 NO | 
| motor starter type | direct on-line contactor | 
| auxiliary contacts type | type instantaneous 1 NC | 
| operating time | 10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing | 
| hold-in power consumption in VA | 4.5-4.5 VA (at 20 °C) | 
| inrush power in VA | 30-30 VA (at 20 °C) | 
| non overlap distance | 0.5 mm | 
| connections - terminals | screw clamp terminals 1 cable(s) 1.5-4 mm²solid, screw clamp terminals 2 cable(s) 1.5-4 mm²solid, screw clamp terminals 2 cable(s) 0.75-4 mm²flexible without cable end, screw clamp terminals 1 cable(s) 0.75-4 mm²flexible without cable end, screw clamp terminals 1 cable(s) 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 cable(s) 0.34-1.5 mm²flexible with cable end | 
| height | 58 mm | 
| mounting support | plate, rail | 
| compatibility code | LC1K | 
| width | 45 mm | 
| depth | 57 mm | 
| operating altitude | 2000 m without derating | 
| IP degree of protection | IP2x conforming to VDE 0106 | 
| poles description | 3P | 
| tightening torque | 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 | 
| electrical durability | 1.3 Mcycles 6 A AC-3 at Ue <= 440 V | 
| device application | control | 
| [Ue] rated operational voltage | power circuit: 690 V AC 50/60 Hz, signalling circuit: <= 690 V AC 50/60 Hz | 
| utilisation category | AC-4, AC-3 | 
| [Ui] rated insulation voltage | power circuit: 690 V conforming to IEC 60947-4-1, power circuit: 600 V conforming to UL 508, signalling circuit: 690 V conforming to IEC 60947-4-1, signalling circuit: 690 V conforming to IEC 60947-5-1, signalling circuit: 600 V conforming to UL 508, power circuit: 600 V conforming to CSA C22.2 No 14, signalling circuit: 600 V conforming to CSA C22.2 No 14 | 
| auxiliary contact composition | 1 NC | 
| control circuit voltage limits | drop-out: 0.2...0.75 Uc (at <50 °C), operational: 0.8...1.15 Uc (at <50 °C) | 
| associated fuse rating | 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660 | 
| flame retardance | V1 conforming to UL 94, requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102 | 
| minimum switching voltage | 17 V for signalling circuit | 
| maximum operating rate | 3600 cyc/h | 
| signalling circuit frequency | <= 400 Hz | 
| protective treatment | TC conforming to IEC 60068, TC conforming to DIN 50016 | 
| motor power kW | 1.5 kW at 220...230 V AC 50/60 Hz AC-3, 2.2 kW at 380...415 V AC 50/60 Hz AC-3, 3 kW at 440 V AC 50/60 Hz AC-3, 3 kW at 480 V AC 50/60 Hz AC-3, 3 kW at 500...600 V AC 50/60 Hz AC-3, 3 kW at 660...690 V AC 50/60 Hz AC-3, 1.5 kW at 400 V AC 50/60 Hz AC-4 | 
| heat dissipation | 1.3-1.3 W | 