Schneider Electric

TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NO aux. - 220...230 V AC coil - LC1K0610M7

In stock
SKU
LC1K0610M7
38%
Special Price Rp 255.322 Regular Price Rp 411.810
Details

TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2.2kW@400V).

It provides a 220V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals.

For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications.

Very compact (45mm width), DIN-rail mounting or screw fixing.

Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

More Information
More Information
Attribute Value
SKU LC1K0610M7
product certifications CSA, UL
ambient air temperature for storage -50-80 °C
overvoltage category III
[Icw] rated short-time withstand current 90 A 50 °C - 1 s for power circuit, 85 A 50 °C - 5 s for power circuit, 80 A 50 °C - 10 s for power circuit, 60 A 50 °C - 30 s for power circuit, 45 A 50 °C - 1 min for power circuit, 40 A 50 °C - 3 min for power circuit, 20 A 50 °C - >= 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit
range of product TeSys K
product or component type Kontaktor
net weight 0.18 kg
standards BS 5424, IEC 60947, VDE 0660, NF C 63-110
mechanical durability 10 Mcycles
device short name LC1K
range TeSys K
average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ie] rated operational current 6 A at <= 440 V AC AC-3 for power circuit
[Uc] control circuit voltage 220...230 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
product name TeSys K
minimum switching current 5 mA for signalling circuit
mechanical robustness vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6, shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
[Ith] conventional free air thermal current 20 A (at 50 °C) for power circuit, 10 A (at 50 °C) for signalling circuit
control circuit type AC at 50/60 Hz
safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
contactor application motor control
contactor coil voltage 220 V AC standard, 230 V AC standard
insulation resistance > 10 MOhm for signalling circuit
rated breaking capacity 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947, 110 A at 415 V conforming to IEC 60947, 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947
Irms rated making capacity 110 A AC for signalling circuit conforming to IEC 60947, 110 A AC for power circuit conforming to NF C 63-110, 110 A AC for power circuit conforming to IEC 60947
power range 1.1-2 kW at 200-240 V 3 phases, 2.2-3 kW at 380-440 V 3 phases, 2.2-3 kW at 480-500 V 3 phases, 1.1-2 kW at 380-440 V 3 phases, 1.1-2 kW at 480-500 V 3 phases, 0-0.5 kW at 200-240 V 3 phases, 0.55-1 kW at 200-240 V 3 phases, 0-0.5 kW at 380-440 V 3 phases, 0.55-1 kW at 380-440 V 3 phases, 0-0.5 kW at 480-500 V 3 phases, 0.55-1 kW at 480-500 V 3 phases
pole contact composition 3 NO
motor starter type direct on-line contactor
auxiliary contacts type type instantaneous 1 NO
operating time 10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing
hold-in power consumption in VA 4.5-4.5 VA (at 20 °C)
inrush power in VA 30-30 VA (at 20 °C)
non overlap distance 0.5 mm
connections - terminals screw clamp terminals 1 cable(s) 1.5-4 mm²solid, screw clamp terminals 2 cable(s) 1.5-4 mm²solid, screw clamp terminals 2 cable(s) 0.75-4 mm²flexible without cable end, screw clamp terminals 1 cable(s) 0.75-4 mm²flexible without cable end, screw clamp terminals 1 cable(s) 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 cable(s) 0.34-1.5 mm²flexible with cable end
height 58 mm
mounting support plate, rail
compatibility code LC1K
width 45 mm
depth 57 mm
operating altitude 2000 m without derating
IP degree of protection IP2x conforming to VDE 0106
poles description 3P
tightening torque 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2
electrical durability 1.3 Mcycles 6 A AC-3 at Ue <= 440 V
device application control
[Ue] rated operational voltage power circuit: 690 V AC 50/60 Hz, signalling circuit: <= 690 V AC 50/60 Hz
utilisation category AC-4, AC-3
[Ui] rated insulation voltage power circuit: 690 V conforming to IEC 60947-4-1, power circuit: 600 V conforming to UL 508, signalling circuit: 690 V conforming to IEC 60947-4-1, signalling circuit: 690 V conforming to IEC 60947-5-1, signalling circuit: 600 V conforming to UL 508, power circuit: 600 V conforming to CSA C22.2 No 14, signalling circuit: 600 V conforming to CSA C22.2 No 14
auxiliary contact composition 1 NO
control circuit voltage limits drop-out: 0.2...0.75 Uc (at <50 °C), operational: 0.8...1.15 Uc (at <50 °C)
associated fuse rating 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
flame retardance V1 conforming to UL 94, requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
minimum switching voltage 17 V for signalling circuit
maximum operating rate 3600 cyc/h
signalling circuit frequency <= 400 Hz
protective treatment TC conforming to IEC 60068, TC conforming to DIN 50016
motor power kW 1.5 kW at 220...230 V AC 50/60 Hz AC-3, 2.2 kW at 380...415 V AC 50/60 Hz AC-3, 3 kW at 440 V AC 50/60 Hz AC-3, 3 kW at 480 V AC 50/60 Hz AC-3, 3 kW at 500...600 V AC 50/60 Hz AC-3, 3 kW at 660...690 V AC 50/60 Hz AC-3, 1.5 kW at 400 V AC 50/60 Hz AC-4
heat dissipation 1.3-1.3 W
PT. Telesindo Citra Sejahtera © 2025 All Rights Reserved.