Schneider Electric

TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 220...230 V AC coil - LC1K0910M7

In stock
SKU
LC1K0910M7
38%
Special Price Rp 267.710 Regular Price Rp 431.790
Details

TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1.

It provides a 220V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals.

For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications.

Very compact (45mm width), DIN-rail mounting or screw fixing.

Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

More Information
More Information
Attribute Value
SKU LC1K0910M7
product certifications CSA, UL
overvoltage category III
range of product TeSys K
product or component type Kontaktor
range TeSys K
average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ie] rated operational current 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit, 9 A at <= 440 V AC AC-3 for power circuit, 16 A (at <70 °C) at 690 V AC AC-1 for power circuit
[Uc] control circuit voltage 220...230 V AC 50/60 Hz
product name TeSys K
minimum switching current 5 mA for signalling circuit
mechanical robustness vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6, shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
[Ith] conventional free air thermal current 20 A (at 50 °C) for power circuit, 10 A (at 50 °C) for signalling circuit
control circuit type AC at 50/60 Hz
safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
contactor application motor control, resistive load
insulation resistance > 10 MOhm for signalling circuit
rated breaking capacity 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947, 110 A at 415 V conforming to IEC 60947, 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947
Irms rated making capacity 110 A AC for signalling circuit conforming to IEC 60947, 110 A AC for power circuit conforming to NF C 63-110, 110 A AC for power circuit conforming to IEC 60947
pole contact composition 3 NO
auxiliary contacts type type instantaneous 1 NO
operating time 10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing
hold-in power consumption in VA 4.5-4.5 VA (at 20 °C)
inrush power in VA 30-30 VA (at 20 °C)
non overlap distance 0.5 mm
compatibility code LC1K
operating altitude 2000 m without derating
poles description 3P
device application control
utilisation category AC-4, AC-3, AC-1
auxiliary contact composition 1 NO
control circuit voltage limits drop-out: 0.2...0.75 Uc (at <50 °C), operational: 0.8...1.15 Uc (at <50 °C)
associated fuse rating 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
flame retardance V1 conforming to UL 94, requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
minimum switching voltage 17 V for signalling circuit
maximum operating rate 3600 cyc/h
signalling circuit frequency <= 400 Hz
protective treatment TC conforming to IEC 60068, TC conforming to DIN 50016
motor power kW 2.2 kW at 220...230 V AC 50/60 Hz AC-3, 4 kW at 380...415 V AC 50/60 Hz AC-3, 4 kW at 440 V AC 50/60 Hz AC-3, 4 kW at 480 V AC 50/60 Hz AC-3, 4 kW at 500...600 V AC 50/60 Hz AC-3, 4 kW at 660...690 V AC 50/60 Hz AC-3, 2.2 kW at 400 V AC 50/60 Hz AC-4
heat dissipation 1.3-1.3 W
PT. Telesindo Citra Sejahtera © 2025 All Rights Reserved.