TeSys LR97D electronic overcurrent relay, 7A/690V, to be supplied with 100-120V AC, for protection of motors with a rated current 1.2-6A.

It provides 3 dials to adjust the protection, LOAD (1.2-7A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration.

In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec.

The settings include selectors for 1-phase/3-phase motors and manual/automatic reset, and the device has a reset button, a test/stop button, 2 LED indicators (Run/Trip), 2 auxiliary contacts 1NO/NC for fault signalling.

Settings can be locked by sealing the transparent cover.

For direct attachement to the bottom terminals of a 3-pole contactor LC1D09-D38, with screw clamp terminals on bottom, the separate mounting from the contactor is possible using the terminal block LAD7B106 (to be ordered separately).

Multi-standards certified (IEC, UL, CSA, CCC, EAC), compliant RoHs/Reach.

More Information
More Information
Attribute Value
SKU LR97D07F7
product certifications GOST, CSA, UL
ambient air temperature for storage -30-80 °C
ambient air temperature for operation -25-60 °C conforming to IEC 60947-4-1
reset automatic reset 120 s fixed, electrical by interruption of power supply for minimum 0.1 s, manual reset
resistance to electrostatic discharge 6 kV in indirect mode, 8 kV in air
time range 0.2...10 s - O-time knob, 0.3...10 s - O-time knob, 0.5..30 s - D-time knob
product or component type Electronic Over Current Relay
net weight 0.172 kg
standards IEC 60947, IEC 60255-6
device short name LR97
range TeSys LR
product compatibility LC1D09...D38
product name TeSys D
[Ith] conventional free air thermal current 3 A for control circuit
[Us] rated supply voltage 100...120 V AC
signalling function 2 LEDs
relay application sensitivity to phase failure, locked rotor, mechanical jamming I > 3 x Isetting, overload Imax > Isetting
tripping threshold 1.2...6 A
resistance to radiated fields 10 V/m level 3
maximum power 28 W at 110 V DC conforming to IEC 60947, 28 W at 220 V DC conforming to IEC 60947, 55 W at 24 V DC conforming to IEC 60947, 55 W at 48 V DC conforming to IEC 60947, 140 VA at 48 V AC conforming to IEC 60947, 360 VA at 110 V AC conforming to IEC 60947, 360 VA at 220 V AC conforming to IEC 60947, 70 VA at 24 V AC conforming to IEC 60947
network frequency 50...60 Hz
connections - terminals control circuit: cable 1 x 1-25 mm²flexible with cable end, control circuit: lug-clamp 1 x 1-25 mm²flexible without cable end, control circuit: lug-clamp 2 x 1-25 mm²flexible with cable end, control circuit: lug-clamp 2 x 1-25 mm²flexible without cable end, control circuit: cable 1 x 1-25 mm²flexible without cable end, power circuit: cable 1 x 1-4 mm²flexible with cable end, power circuit: cable 1 x 1.5-10 mm²flexible without cable end, power circuit: lug-clamp 1 x 1-4 mm²flexible with cable end, power circuit: lug-clamp 1 x 1.5-10 mm²flexible without cable end, control circuit: cable 2 x 1-25 mm²flexible with cable end, control circuit: cable 2 x 1-25 mm²flexible without cable end, control circuit: lug-clamp 1 x 1-25 mm²flexible with cable end
height 67.5 mm
mounting support rail, direct on contactor
compatibility code LR97
width 45 mm
depth 67.5 mm
vibration resistance 4 gn conforming to IEC 60068-2-6
operating altitude 2000 m
dielectric strength 2 V 50 Hz conforming to IEC 60255-5
IP degree of protection IP20 conforming to IEC 60529
network type AC
tightening torque control circuit: 0.6...1.2 N.m on lug-clamp, power circuit: 2 N.m on cable
[Ue] rated operational voltage 600 V AC 50/60 Hz for power circuit conforming to CSA, 600 V AC 50/60 Hz for power circuit conforming to UL, 690 V AC 50/60 Hz for power circuit conforming to IEC 60947-4-1
Quantity per set set of 10
protection type BS fuse 3 A - for control circuit, GB2 circuit breaker 3 A - for control circuit, gG fuse 3 A - for control circuit
[Ui] rated insulation voltage power circuit: 690 V conforming to IEC 60947-4-1, power circuit: 600 V conforming to CSA, power circuit: 600 V conforming to UL
protective treatment TH conforming to IEC 60068
fire resistance 850 °C conforming to IEC 60695-2-1
contacts type and composition 1 C/O
shock resistance 15 gn 11 ms conforming to IEC 60068-2-7
thermal protection adjustment range 1.2-7 A
surge withstand 6 kV conforming to IEC 61000-4-5
resistance to fast transients 2 kV
phase failure sensitivity < 3 s
disturbance radiated/conducted 10 V conforming to EN 61000-4-6, class A conforming to EN 55011