Schneider Electric
TeSys LRF - electronic thermal overload relay - 48...80 A - class 10 - LR9F5363
Out of stock
SKU
LR9F5363
Details
TeSys LR9F electronic overload relay, thermal setting range 48-80A, class 10, for protection of motors 30-37kW@400V.
to be mounted directly below a TeSys F 3-pole contactor LC1 F115, F150, F185, use of a support mounting plate LA7F901 is recommended (to be ordered separately).
Motor protection includes thermal overload of 1-phase and 3-phase motors, phase failure, phase unbalance, prolonged starting times, stalled rotor conditions.
On the front of the relay, it provides a thermal adjustement dial, buttons for test, stop & reset, a trip indicator, trip auxiliary contacts 1NO+1NC.
Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHs/Reach).
More Information
Attribute | Value |
---|---|
SKU | LR9F5363 |
product certifications | CSA, UL |
ambient air temperature for storage | -40-85 °C |
ambient air temperature for operation | -20-55 °C conforming to IEC 60255-8 |
reset | manual reset on front relay |
rated power in W | 100 VA at 24 V AC, 600 VA at 380 V AC, 600 VA at 600 V AC, 100 W at 24 V DC, 100 W at 48 V DC, 200 VA at 48 V AC, 25 W at 440 V DC, 400 VA at 110 V AC, 45 W at 220 V DC, 50 W at 110 V DC, 600 VA at 220 V AC |
product or component type | Relay Beban Lebih Termal |
current consumption | <= 5 mA no-load |
net weight | 0.9 kg |
standards | EN 60947-4-1, IEC 60947-4-1, VDE 0660, IEC 60255-17, IEC 60255-8 |
device short name | LR9F |
range | TeSys LRF |
product compatibility | LC1F115...LC1F185 |
product name | TeSys LRF |
mechanical robustness | shocks: 13 Gn for 11 ms conforming to IEC 60068-2-7, vibrations 5...300 Hz: 2 Gn conforming to IEC 60068-2-6 |
[Ith] conventional free air thermal current | 5 A for control circuit |
electromagnetic compatibility | resistance to electrostatic discharge: 6 kV in indirect mode conforming to IEC 61000-4-2, resistance to electrostatic discharge: 8 kV in air conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test: 10 V/m conforming to IEC 61000-4-3, fast transients immunity test: 2 kV conforming to IEC 61000-4-4 |
relay application | motor protection |
tripping threshold | 1.12 +/- 0.06 In tripping conforming to IEC 60947-4-1 |
network frequency | 50/60 Hz |
connections - terminals | control circuit: screw clamp terminals 1 cable 0.75-2.5 mm² - cable stiffness: flexible - with cable end, control circuit: screw clamp terminals 1 cable 0.75-2.5 mm² - cable stiffness: solid, control circuit: screw clamp terminals 1 cable 0.75-4 mm² - cable stiffness: flexible - without cable end, control circuit: screw clamp terminals 2 cable 1-1.5 mm² - cable stiffness: flexible - with cable end, control circuit: screw clamp terminals 2 cable 1-2.5 mm² - cable stiffness: flexible - without cable end, control circuit: screw clamp terminals 2 cable 1-1 mm² - cable stiffness: solid, power circuit: lugs-ring terminals M8 |
height | 96 mm |
mounting support | plate, direct on contactor |
compatibility code | LR9F |
width | 115 mm |
depth | 123.5 mm |
operating altitude | <= 2000 m without derating |
dielectric strength | 6 kV 50 Hz conforming to IEC 255-5 |
IP degree of protection | IP20 conforming to IEC 60529, IP20 conforming to VDE 0106 |
network type | AC |
tightening torque | control circuit: 1.2 N.m on screw clamp terminals, power circuit: 18 N.m on screw clamp terminals |
control type | dial white full-load current adjustment, test button red, push-button red reset, push-button stop |
[Ue] rated operational voltage | 1000 V AC 50/60 Hz for power circuit conforming to VDE 0110 group C |
local signalling | trip indicator |
[Ui] rated insulation voltage | power circuit: 1000 V AC conforming to IEC 60947-4 |
protective treatment | TH |
fire resistance | 850 °C conforming to IEC 60695-2-1 |
contacts type and composition | 1 NO + 1 NC |
thermal protection adjustment range | 48-80 A |
supply voltage limits | 17-32 V |
surge withstand | 4 kV conforming to IEC 61000-4-5 |
phase failure sensitivity | tripping in 4 s +/- 20 % conforming to IEC 60947-4-1 |
thermal overload class | class 10 conforming to IEC 60947-4 |
switching capacity in mA | 0...150 mA |
maximum voltage drop | <2.5 V closed state |
temperature compensation | -20-70 °C |