TeSys T extension module LTME - 24 V DC - LTMEV40BD
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor.
TeSys T manages most critical processes while reducing downtime and increasing productivity.
TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols.
TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range.
TeSys T has a number of components that increase the flexibility of the system.
This expansion module adds functionalities to the TeSys T controller.
It adds voltage mesurement between phases up to 690 V nominal and 4 additional inputs.
Module has 4 discrete logic inputs.
24 VDC is used to power the module.
Module has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
Attribute | Value |
---|---|
SKU | LTMEV40BD |
product certifications | EAC, CCC, LROS (Lloyds register of shipping), BV, GL, RINA, CSA, DNV, UL, C-Tick, ATEX, ABS, RMRoS, NOM, KERI |
ambient air temperature for storage | -40-80 °C |
overvoltage category | III |
pollution degree | 3 |
ambient air temperature for operation | -20-60 °C |
current state 1 guaranteed | logic input: < 15 V and 2...15 mA for 15 ms |
product or component type | Kontaktor |
net weight | 0.21 kg |
standards | CSA C22.2 No 14, EN 60947-4-1, IEC 60947-4-1, UL 508, IACS E10 |
device short name | LTME |
range | TeSys T |
range compatibility | TeSys T LTMR motor controller |
[Uimp] rated impulse withstand voltage | 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1, 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 |
product name | TeSys T |
mechanical robustness | vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6, vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6, shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27 |
[Us] rated supply voltage | 24 V DC |
electromagnetic compatibility | electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2, control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5, communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5, fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4, fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4, conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6, control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5, voltage inputs: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5, voltage inputs: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 |
input current | 7 mA |
logic input number | 4 |
connections - terminals | control circuit: connector 1 cable(s) 0.25-2.5 mm² (AWG 24...AWG 14) flexible with cable end, control circuit: connector 1 cable(s) 0.2-2.5 mm² (AWG 24...AWG 14) flexible without cable end, control circuit: connector 1 cable(s) 0.25-2.5 mm² (AWG 24...AWG 14) flexible without cable end, control circuit: connector 1 cable(s) 0.2-2.5 mm² (AWG 24...AWG 14) solid without cable end, control circuit: connector 2 cable(s) 0.2-1 mm² (AWG 24...AWG 14) flexible with cable end, control circuit: connector 2 cable(s) 0.2-1.5 mm² (AWG 24...AWG 14) flexible without cable end, control circuit: connector 2 cable(s) 0.5-1.5 mm² (AWG 24...AWG 14) flexible without cable end, control circuit: connector 2 cable(s) 0.2-1 mm² (AWG 24...AWG 14) solid without cable end |
height | 61 mm |
compatibility code | LTME |
width | 45 mm |
depth | 120.7 mm |
operating altitude | <= 2000 m without derating |
IP degree of protection | IP20 |
tightening torque | control circuit: 0.5-0.6 N.m flat screwdriver 3 mm |
device application | equipment monitoring and control |
connection pitch | 5.08 mm |
[Ui] rated insulation voltage | 690 V conforming to EN/IEC 60947-1, 690 V conforming to CSA C22.2 No 14, 690 V conforming to UL 508 |
maximum operating rate | 1800 cyc/h |
protective treatment | 12 x 24 hour cycles conforming to EN/IEC 60068-2-30, 48 h conforming to EN/IEC 60070-2-11, TH conforming to EN/IEC 60068 |
fire resistance | 650 °C conforming to EN/IEC 60695-2-12, 960 °C conforming to UL 94 |
contacts type and composition | without |
measurement accuracy | 1 % voltage (100...830 V), 3 % power factor, 5 % active and reactive power |
metering type | active power P, P1, P2, P3, reactive power Q, Q1, Q2, Q3, frequency, voltage U21, U32, U13, V1, V2, V3, imbalance voltage, calculated active and reactive energy (+/- W.h, +/- VAR.h), power factor |
current state 0 guaranteed | logic input: < 5 V and <= 15 mA for 5 ms |
supply | via the controller |
maximum operating frequency | 2 Hz |