Attribute Value
SKU LTMR27PBD
product certifications EAC, CCC, LROS (Lloyds register of shipping), BV, GL, RINA, CSA, DNV, UL, C-Tick, ATEX, ABS, RMRoS, NOM, KERI
ambient air temperature for storage -40-80 °C
overvoltage category III
pollution degree 3
ambient air temperature for operation -20-60 °C
current state 1 guaranteed logic input: < 15 V and 2...15 mA for 15 ms
product or component type Kontaktor
current consumption 56...127 mA
net weight 0.53 kg
standards CSA C22.2 No 14, EN 60947-4-1, IEC 60947-4-1, UL 508, IACS E10
device short name LTMR
range TeSys T
[Uimp] rated impulse withstand voltage 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1, 0.8 kV communication circuit conforming to EN/IEC 60947-4-1, 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
product name TeSys T
mechanical robustness vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6, vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6, shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
[Us] rated supply voltage 24 V DC
electromagnetic compatibility electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2, control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5, communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5, relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5, relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5, radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3, fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4, fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4, voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11, conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6, temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5, temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5, control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
input current 7 mA
permissible power 480 VA (AC-15), Ie = 2 A, 500000 cycles (output), 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
network and machine diagnosis type motor control command recording, running hours counter/operating time, trip history information, fault recording, starting current and time, phase fault and earth fault trip counters, remaining operating time before overload tripping, waiting time after overload tripping, trip context information, event recording
logic input number 6
connections - terminals control circuit: connector 1 cable(s) 0.25-2.5 mm² (AWG 24...AWG 14) flexible with cable end, control circuit: connector 1 cable(s) 0.2-2.5 mm² (AWG 24...AWG 14) flexible without cable end, control circuit: connector 1 cable(s) 0.25-2.5 mm² (AWG 24...AWG 14) flexible without cable end, control circuit: connector 1 cable(s) 0.2-2.5 mm² (AWG 24...AWG 14) solid without cable end, control circuit: connector 2 cable(s) 0.2-1 mm² (AWG 24...AWG 14) flexible with cable end, control circuit: connector 2 cable(s) 0.2-1.5 mm² (AWG 24...AWG 14) flexible without cable end, control circuit: connector 2 cable(s) 0.5-1.5 mm² (AWG 24...AWG 14) flexible without cable end, control circuit: connector 2 cable(s) 0.2-1 mm² (AWG 24...AWG 14) solid without cable end
height 61 mm
compatibility code LTMR
width 91 mm
depth 122.5 mm
operating altitude <= 2000 m without derating
IP degree of protection IP20
tightening torque control circuit: 0.5-0.6 N.m flat screwdriver 3 mm
device application equipment monitoring and control
protection type overload, locked rotor, phase unbalance, earth-leakage protection, thermal protection, load fluctuation, power factor variation, phase failure, reverse polarity protection, overload (long time), thermal overload protection
connection pitch 5.08 mm
[Ui] rated insulation voltage 690 V conforming to EN/IEC 60947-1, 690 V conforming to CSA C22.2 No 14, 690 V conforming to UL 508
associated fuse rating 4 A gG for output, 0.5 A gG for control circuit
maximum operating rate 1800 cyc/h
protective treatment 12 x 24 hour cycles conforming to EN/IEC 60068-2-30, 48 h conforming to EN/IEC 60070-2-11, TH conforming to EN/IEC 60068
fire resistance 650 °C conforming to EN/IEC 60695-2-12, 960 °C conforming to UL 94
contacts type and composition 1 NO + 1 NC fault signal, 3 NO
load current 5 A at 250 V AC for logic output, 5 A at 30 V DC for logic output
supply voltage limits 20.4-26.24 V DC
measurement current 1.35-27 A
communication port protocol Profibus DP
measurement accuracy 5...15 % earth fault current internal measurement, 1 % voltage (100...830 V), 3 % power factor, 5 % earth fault current external measurement, +/- 30 min/year internal clock, 0,02 temperature, 1 % current, 5 % active and reactive power
metering type average current Iavg, earth-fault current, imbalance current, phase current I1, I2, I3 RMS, temperature
current state 0 guaranteed logic input: < 5 V and <= 15 mA for 5 ms
web services web server
short-circuit withstand 100 kA conforming to EN/IEC 60947-4-1
maximum operating frequency 2 Hz
bus type Profibus DP polarised 2-wire RS485 interface, addressing 1...125, transmission rate 9.6 kbit/s...12 Mbit/s, SUB-D 9 with 2 shielded twisted pairs, type A, Profibus DP polarised 2-wire RS485 interface, addressing 1...125, transmission rate 9.6 kbit/s...12 Mbit/s, terminal block with 2 shielded twisted pairs, type A