Schneider Electric
TeSys U standard control unit LUCA - class 10 - 4.5...18 A - 110...220 V DC/AC - LUCA18FU
Out of stock
SKU
LUCA18FU
Details
TeSys U standard control unit to be inserted in power bases LUB32, LUB32, LUB38 to form a TeSys U starter controller, for 3-phase motor applications up to 7.5kW@400V.
It provides full protection to motors with a rated current Ir 4.5-18A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only).
To be used with a 110-240V AC / 110-220V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base).
Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
More Information
Attribute | Value |
---|---|
SKU | LUCA18FU |
product certifications | EAC, CCC, CSA, UL, CE, ATEX, ASEFA, Marine |
ambient air temperature for storage | -40-85 °C |
ambient air temperature for operation | -25-70 °C |
resistance to electrostatic discharge | 8 kV level 3 in open air conforming to IEC 61000-4-2, 8 kV level 4 on contact conforming to IEC 61000-4-2 |
range of product | TeSys U |
product or component type | Motor Starter |
net weight | 0.135 kg |
standards | EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier |
device short name | LUCA |
range | TeSys Ultra |
product compatibility | power base LUB32, power base LUB38, power base LUB320, power base LUB380, reversing contactor breaker LU2B32FU, reversing contactor breaker LU2B38FU |
[Uc] control circuit voltage | 110...240 V AC, 110...220 V DC |
product name | TeSys U |
operating time | 35 ms opening with LUB32 for control circuit, 35 ms opening with LUB38 for control circuit, 50 ms closing with LUB32 for control circuit, 50 ms closing with LUB38 for control circuit |
immunity to microbreaks | 3 ms |
tripping threshold | 14.2 x Ir +/- 20 % |
resistance to radiated fields | 10 V/m 3 conforming to IEC 61000-4-3 |
typical current consumption | 280 mA at 110...240 V AC I maximum while closing with LUB32, 280 mA at 110...240 V AC I maximum while closing with LUB38, 280 mA at 110...220 V DC I maximum while closing with LUB32, 280 mA at 110...220 V DC I maximum while closing with LUB38, 25 mA at 110...240 V AC I rms sealed with LUB32, 25 mA at 110...240 V AC I rms sealed with LUB38, 25 mA at 110...220 V DC I rms sealed with LUB32, 25 mA at 110...220 V DC I rms sealed with LUB38 |
safe separation of circuit | 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 |
network frequency | 40...60 Hz |
height | 66 mm |
compatibility code | LUCA |
width | 45 mm |
depth | 60 mm |
vibration resistance | 2 gn, 5-300 Hz, power poles open conforming to IEC 60068-2-6, 4 gn, 5-300 Hz, power poles closed conforming to IEC 60068-2-6 |
operating altitude | 2000 m |
IP degree of protection | IP20 front panel and wired terminals conforming to IEC 60947-1, IP20 other faces conforming to IEC 60947-1, IP40 front panel outside connection zone conforming to IEC 60947-1 |
device application | motor protection, motor control |
[Ue] rated operational voltage | 690 V AC |
load type | 3-phase motor - cooling: self-cooled |
fixing mode | plug-in (front face) |
utilisation category | AC-43, AC-44, AC-41 |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-6-2, 600 V conforming to UL 60947-4-1, 600 V conforming to CSA C22.2 No 60947-4-1 |
control circuit voltage limits | 88...264 V for AC circuit 110...240 V in operation, 88...242 V for DC circuit 110...220 V in operation, 55 V for AC circuit 110...240 V drop-out, 55 V for DC circuit 110...220 V drop-out |
protective treatment | TH conforming to IEC 60068 |
fire resistance | 960 °C parts supporting live components conforming to IEC 60695-2-12, 650 °C conforming to IEC 60695-2-12 |
motor power kW | 7.5 kW at 400...440 V AC 50/60 Hz, 9 kW at 500 V AC 50/60 Hz, 15 kW at 690 V AC 50/60 Hz |
heat dissipation | 3-3 W for control circuit with LUB32, 3-3 W for control circuit with LUB38 |
shock resistance | 10 gn power poles open conforming to IEC 60068-2-27, 15 gn power poles closed conforming to IEC 60068-2-27 |
function available | earth fault protection, protection against phase failure and phase imbalance, protection against overload and short-circuit, manual reset |
thermal protection adjustment range | 4.5-18 A |
product specific application | basic protection requirements for motor starters: overload and short-circuit |
resistance to fast transients | 2 kV class 3 serial link conforming to IEC 61000-4-4, 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 |
phase failure sensitivity | yes |
thermal overload class | class 10 - frequency limit: 40-60 Hz - temperature compensation: -25-70 °C conforming to IEC 60947-6-2, class 10 - frequency limit: 40-60 Hz - temperature compensation: -25-70 °C conforming to UL 508 |
non-dissipating shock wave | 1 kV serial mode conforming to IEC 60947-6-2, 2 kV common mode conforming to IEC 60947-6-2 |
immunity to voltage dips | 70 % / 500 ms conforming to IEC 61000-4-11 |
immunity to radioelectric fields | 10 V conforming to IEC 61000-4-6 |