TeSys U standard control unit to be inserted in power bases LUB32, LUB32, LUB38 to form a TeSys U starter controller, for 3-phase motor applications up to 7.5kW@400V.
It provides full protection to motors with a rated current Ir 4.5-18A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only).
To be used with a 110-240V AC / 110-220V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base).
Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
                        More Information
                    
                        | Attribute | Value | 
|---|---|
| SKU | LUCA18FU | 
| product certifications | EAC, CCC, CSA, UL, CE, ATEX, ASEFA, Marine | 
| ambient air temperature for storage | -40-85 °C | 
| ambient air temperature for operation | -25-70 °C | 
| resistance to electrostatic discharge | 8 kV level 3 in open air conforming to IEC 61000-4-2, 8 kV level 4 on contact conforming to IEC 61000-4-2 | 
| range of product | TeSys U | 
| product or component type | Motor Starter | 
| net weight | 0.135 kg | 
| standards | EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier | 
| device short name | LUCA | 
| range | TeSys Ultra | 
| product compatibility | power base LUB32, power base LUB38, power base LUB320, power base LUB380, reversing contactor breaker LU2B32FU, reversing contactor breaker LU2B38FU | 
| [Uc] control circuit voltage | 110...240 V AC, 110...220 V DC | 
| product name | TeSys U | 
| operating time | 35 ms opening with LUB32 for control circuit, 35 ms opening with LUB38 for control circuit, 50 ms closing with LUB32 for control circuit, 50 ms closing with LUB38 for control circuit | 
| immunity to microbreaks | 3 ms | 
| tripping threshold | 14.2 x Ir +/- 20 % | 
| resistance to radiated fields | 10 V/m 3 conforming to IEC 61000-4-3 | 
| typical current consumption | 280 mA at 110...240 V AC I maximum while closing with LUB32, 280 mA at 110...240 V AC I maximum while closing with LUB38, 280 mA at 110...220 V DC I maximum while closing with LUB32, 280 mA at 110...220 V DC I maximum while closing with LUB38, 25 mA at 110...240 V AC I rms sealed with LUB32, 25 mA at 110...240 V AC I rms sealed with LUB38, 25 mA at 110...220 V DC I rms sealed with LUB32, 25 mA at 110...220 V DC I rms sealed with LUB38 | 
| safe separation of circuit | 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 | 
| network frequency | 40...60 Hz | 
| height | 66 mm | 
| compatibility code | LUCA | 
| width | 45 mm | 
| depth | 60 mm | 
| vibration resistance | 2 gn, 5-300 Hz, power poles open conforming to IEC 60068-2-6, 4 gn, 5-300 Hz, power poles closed conforming to IEC 60068-2-6 | 
| operating altitude | 2000 m | 
| IP degree of protection | IP20 front panel and wired terminals conforming to IEC 60947-1, IP20 other faces conforming to IEC 60947-1, IP40 front panel outside connection zone conforming to IEC 60947-1 | 
| device application | motor protection, motor control | 
| [Ue] rated operational voltage | 690 V AC | 
| load type | 3-phase motor - cooling: self-cooled | 
| fixing mode | plug-in (front face) | 
| utilisation category | AC-43, AC-44, AC-41 | 
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-6-2, 600 V conforming to UL 60947-4-1, 600 V conforming to CSA C22.2 No 60947-4-1 | 
| control circuit voltage limits | 88...264 V for AC circuit 110...240 V in operation, 88...242 V for DC circuit 110...220 V in operation, 55 V for AC circuit 110...240 V drop-out, 55 V for DC circuit 110...220 V drop-out | 
| protective treatment | TH conforming to IEC 60068 | 
| fire resistance | 960 °C parts supporting live components conforming to IEC 60695-2-12, 650 °C conforming to IEC 60695-2-12 | 
| motor power kW | 7.5 kW at 400...440 V AC 50/60 Hz, 9 kW at 500 V AC 50/60 Hz, 15 kW at 690 V AC 50/60 Hz | 
| heat dissipation | 3-3 W for control circuit with LUB32, 3-3 W for control circuit with LUB38 | 
| shock resistance | 10 gn power poles open conforming to IEC 60068-2-27, 15 gn power poles closed conforming to IEC 60068-2-27 | 
| function available | earth fault protection, protection against phase failure and phase imbalance, protection against overload and short-circuit, manual reset | 
| thermal protection adjustment range | 4.5-18 A | 
| product specific application | basic protection requirements for motor starters: overload and short-circuit | 
| resistance to fast transients | 2 kV class 3 serial link conforming to IEC 61000-4-4, 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 | 
| phase failure sensitivity | yes | 
| thermal overload class | class 10 - frequency limit: 40-60 Hz - temperature compensation: -25-70 °C conforming to IEC 60947-6-2, class 10 - frequency limit: 40-60 Hz - temperature compensation: -25-70 °C conforming to UL 508 | 
| non-dissipating shock wave | 1 kV serial mode conforming to IEC 60947-6-2, 2 kV common mode conforming to IEC 60947-6-2 | 
| immunity to voltage dips | 70 % / 500 ms conforming to IEC 61000-4-11 | 
| immunity to radioelectric fields | 10 V conforming to IEC 61000-4-6 | 