TeSys U standard control unit to be inserted in power bases LUB32, LUB38 to form a TeSys U starter controller, for 3-phase motor applications up to 15kW@400V.

It provides full protection to motors with a rated current Ir 8-32A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only).

To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base).

Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

More Information
More Information
Attribute Value
SKU LUCA32BL
product certifications EAC, CCC, CSA, UL, CE, ATEX, ASEFA, Marine
ambient air temperature for storage -40-85 °C
ambient air temperature for operation -25-70 °C
resistance to electrostatic discharge 8 kV level 3 in open air conforming to IEC 61000-4-2, 8 kV level 4 on contact conforming to IEC 61000-4-2
range of product TeSys U
product or component type Motor Starter
net weight 0.135 kg
standards EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier
device short name LUCA
range TeSys Ultra
product compatibility power base LUB32, power base LUB38, power base LUB320, power base LUB380, reversing contactor breaker LU2B32BL, reversing contactor breaker LU2B38BL
[Uc] control circuit voltage 24 V DC
product name TeSys U
operating time 35 ms opening with LUB32 for control circuit, 35 ms opening with LUB38 for control circuit, 70 ms closing with LUB32 for control circuit, 70 ms closing with LUB38 for control circuit
immunity to microbreaks 3 ms
tripping threshold 14.2 x Ir +/- 20 %
resistance to radiated fields 10 V/m 3 conforming to IEC 61000-4-3
typical current consumption 220 mA at 24 V DC I maximum while closing with LUB32, 220 mA at 24 V DC I maximum while closing with LUB38, 80 mA at 24 V DC I rms sealed with LUB32, 80 mA at 24 V DC I rms sealed with LUB38
safe separation of circuit 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
network frequency 40...60 Hz
height 66 mm
compatibility code LUCA
width 45 mm
depth 60 mm
vibration resistance 2 gn, 5-300 Hz, power poles open conforming to IEC 60068-2-6, 4 gn, 5-300 Hz, power poles closed conforming to IEC 60068-2-6
operating altitude 2000 m
IP degree of protection IP20 front panel and wired terminals conforming to IEC 60947-1, IP20 other faces conforming to IEC 60947-1, IP40 front panel outside connection zone conforming to IEC 60947-1
device application motor protection, motor control
[Ue] rated operational voltage 690 V AC
load type 3-phase motor - cooling: self-cooled
fixing mode plug-in (front face)
utilisation category AC-43, AC-44, AC-41
[Ui] rated insulation voltage 690 V conforming to IEC 60947-6-2, 600 V conforming to UL 60947-4-1, 600 V conforming to CSA C22.2 No 60947-4-1
control circuit voltage limits 20...27 V for DC circuit 24 V in operation, 14.5 V for DC circuit 24 V drop-out
protective treatment TH conforming to IEC 60068
fire resistance 960 °C parts supporting live components conforming to IEC 60695-2-12, 650 °C conforming to IEC 60695-2-12
motor power kW 15 kW at 400...440 V AC 50/60 Hz, 15 kW at 500 V AC 50/60 Hz, 18.5 kW at 690 V AC 50/60 Hz
heat dissipation 3-3 W for control circuit with LUB32, 3-3 W for control circuit with LUB38
shock resistance 10 gn power poles open conforming to IEC 60068-2-27, 15 gn power poles closed conforming to IEC 60068-2-27
function available earth fault protection, protection against phase failure and phase imbalance, protection against overload and short-circuit, manual reset
thermal protection adjustment range 8-32 A
product specific application basic protection requirements for motor starters: overload and short-circuit
resistance to fast transients 2 kV class 3 serial link conforming to IEC 61000-4-4, 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
phase failure sensitivity yes
thermal overload class class 10 - frequency limit: 40-60 Hz - temperature compensation: -25-70 °C conforming to IEC 60947-6-2, class 10 - frequency limit: 40-60 Hz - temperature compensation: -25-70 °C conforming to UL 508
immunity to voltage dips 70 % / 500 ms conforming to IEC 61000-4-11
immunity to radioelectric fields 10 V conforming to IEC 61000-4-6