Schneider Electric
VarPlus Logic Power Factor controller - VPL 6 - VPL06N
Out of stock
SKU
VPL06N
Details
VarPlus logic is a simple and efficient Power Controller for a automatic power factor correction equipment to maintain the power factor.
It is a simple and intelligent relay which measures,monitor and Controls the reactive energy.
It comes with Easy Commisioning , Step Size detection and monitoring along with the variour alarms.
VPL06 can be used for 6 steps in a PFC equippment
More Information
Attribute | Value |
---|---|
SKU | VPL06N |
product certifications | EAC, CE, NRTL, cNRTL |
ambient air temperature for storage | -40-85 °C |
ambient air temperature for operation | -20-60 °C |
display size | 56 x 25 mm |
product or component type | Koreksi Faktor Daya |
net weight | 0.6 kg |
mounting mode | flush-mounted |
standards | EN 61010-1, UL 61010-1, IEC 61326-1, IEC 61000-6-4, IEC 61000-6-2 |
mechanical durability | 65000 cycles without maintenance |
device short name | VPL6 |
range | PowerLogic |
product name | VarPlus Logic |
[Us] rated supply voltage | 90...550 V AC, <= 999 kV AC with external VT |
type of measurement | power factor, ambient temperature inside the cubicle, tan φ, individual voltage harmonic, cos φ, operating time, capacitor current overload Irms/I1 |
colour code | front: dark grey RAL 7016 |
device connection | communication protocol: Modbus interface: RS485 |
output type | control relay: 0.2 A 110 V DC, alarm relay: 1 A 48 V DC, control relay: 1 A 48 V DC, control relay: 2 A 400 V AC 50/60 Hz, control relay: 1 A 24 V DC, control relay: 5 A 250 V AC 50/60 Hz, control relay: 5 A 120 V AC 50/60 Hz, fan: 5 A 250 V AC 50/60 Hz, fan: 1 A 48 V DC, alarm relay: 5 A 250 V AC 50/60 Hz |
operating mode | manual or automatic |
number of step output contacts | 6 |
number of quadrant operation for generator application | 4 |
type of alarms | step power loss (< 75 %) / Action: message and alarm contact + step blocked, overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped, total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off, step faulty / Action: message and alarm contact + step blocked, high current (> 6 A CT) / Action: message and alarm contact, hunting (unstable regulation) / Action: message and alarm contact + step blocked, low current (< 15 mA CT) / Action: message and alarm contact, overcompensation / Action: message and alarm contact, capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off, overtemperature (50 °C) / Action: message and alarm contact + step switched off, overtemperature (30 °C) / Action: fan switch |
height | 144 mm |
mounting support | panel - thickness: 1-3 mm |
compatibility code | VPL 6 |
width | 144 mm |
depth | 58 mm |
operating altitude | <= 2000 m |
IP degree of protection | rear face: IP20, front face: IP41 |
provided equipment | user manual |
measurement voltage | 90-550 V AC 50/60 Hz |
cut-out dimensions | 138 x 138 mm |
display type | backlit LCD |
function available | automatic detection, advanced programming (expert), manual programming, any step sequence, automatic initialisation |
time delay range | 1...6500 s (on reconnection), 1...6500 s (on response) |
measurement current | 0-5 A |
information displayed | number of switching cycles per step, remaining step capacity in %, individual step size in kVAr |
measurement accuracy | current +/- 1 %, voltage +/- 1 %, frequency +/- 1 %, energy (P,Q,S) +/- 2 %, cos φ +/- 2 %, total voltage harmonic distortion THD (U) +/- 2 %, individual voltage harmonic +/- 3 %, temperature +/- 3 °C |
data recording | 5 alarms |
metering type | power factor and displacement PF (signed, four quadrant), total current harmonic distortion THD (I), power factor average over lifetime, temperature maximum, phase current I1, I2, I3 RMS on load, active power P, P1, P2, P3 on load, reactive power Q, Q1, Q2, Q3 on load, apparent power S, S1, S2, S3 on load, voltage U21, U32, U13, V1, V2, V3 on load |
input function | switch: 1 x dry contact |
type of setting | choice of stepping programs: auto, choice of stepping programs: LIFO, choice of stepping programs: linear, delay between 2 successive switch on the same step: 5...1200 s, step configuration programming: auto, step configuration programming: off, step configuration programming: fixed, target cos phi: 0.7 inductive...0.7 capacitive, target cos phi: dual cos φ |
service life in hours | 100000 h without maintenance |
mounting location | in cabinet |
input type | phase to phase, insensitive to phase rotation polarity, insensitive to CT polarity, phase to neutral, current input CT...X/5 A and X/1 A |
settings operating mode | manual, automatic |
current of common | 10 A |