VPL06N
Rp 14.735.250
Details

VarPlus logic is a simple and efficient Power Controller for a automatic power factor correction equipment to maintain the power factor.

It is a simple and intelligent relay which measures,monitor and Controls the reactive energy.

It comes with Easy Commisioning , Step Size detection and monitoring along with the variour alarms.

VPL06 can be used for 6 steps in a PFC equippment

More Information
More Information
Attribute Value
SKU VPL06N
product certifications EAC, CE, NRTL, cNRTL
ambient air temperature for storage -40-85 °C
ambient air temperature for operation -20-60 °C
display size 56 x 25 mm
product or component type Koreksi Faktor Daya
net weight 0.6 kg
mounting mode flush-mounted
standards EN 61010-1, UL 61010-1, IEC 61326-1, IEC 61000-6-4, IEC 61000-6-2
mechanical durability 65000 cycles without maintenance
device short name VPL6
range PowerLogic
product name VarPlus Logic
[Us] rated supply voltage 90...550 V AC, <= 999 kV AC with external VT
type of measurement power factor, ambient temperature inside the cubicle, tan φ, individual voltage harmonic, cos φ, operating time, capacitor current overload Irms/I1
colour code front: dark grey RAL 7016
device connection communication protocol: Modbus interface: RS485
output type control relay: 0.2 A 110 V DC, alarm relay: 1 A 48 V DC, control relay: 1 A 48 V DC, control relay: 2 A 400 V AC 50/60 Hz, control relay: 1 A 24 V DC, control relay: 5 A 250 V AC 50/60 Hz, control relay: 5 A 120 V AC 50/60 Hz, fan: 5 A 250 V AC 50/60 Hz, fan: 1 A 48 V DC, alarm relay: 5 A 250 V AC 50/60 Hz
operating mode manual or automatic
number of step output contacts 6
number of quadrant operation for generator application 4
type of alarms step power loss (< 75 %) / Action: message and alarm contact + step blocked, overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped, total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off, step faulty / Action: message and alarm contact + step blocked, high current (> 6 A CT) / Action: message and alarm contact, hunting (unstable regulation) / Action: message and alarm contact + step blocked, low current (< 15 mA CT) / Action: message and alarm contact, overcompensation / Action: message and alarm contact, capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off, overtemperature (50 °C) / Action: message and alarm contact + step switched off, overtemperature (30 °C) / Action: fan switch
height 144 mm
mounting support panel - thickness: 1-3 mm
compatibility code VPL 6
width 144 mm
depth 58 mm
operating altitude <= 2000 m
IP degree of protection rear face: IP20, front face: IP41
provided equipment user manual
measurement voltage 90-550 V AC 50/60 Hz
cut-out dimensions 138 x 138 mm
display type backlit LCD
function available automatic detection, advanced programming (expert), manual programming, any step sequence, automatic initialisation
time delay range 1...6500 s (on reconnection), 1...6500 s (on response)
measurement current 0-5 A
information displayed number of switching cycles per step, remaining step capacity in %, individual step size in kVAr
measurement accuracy current +/- 1 %, voltage +/- 1 %, frequency +/- 1 %, energy (P,Q,S) +/- 2 %, cos φ +/- 2 %, total voltage harmonic distortion THD (U) +/- 2 %, individual voltage harmonic +/- 3 %, temperature +/- 3 °C
data recording 5 alarms
metering type power factor and displacement PF (signed, four quadrant), total current harmonic distortion THD (I), power factor average over lifetime, temperature maximum, phase current I1, I2, I3 RMS on load, active power P, P1, P2, P3 on load, reactive power Q, Q1, Q2, Q3 on load, apparent power S, S1, S2, S3 on load, voltage U21, U32, U13, V1, V2, V3 on load
input function switch: 1 x dry contact
type of setting choice of stepping programs: auto, choice of stepping programs: LIFO, choice of stepping programs: linear, delay between 2 successive switch on the same step: 5...1200 s, step configuration programming: auto, step configuration programming: off, step configuration programming: fixed, target cos phi: 0.7 inductive...0.7 capacitive, target cos phi: dual cos φ
service life in hours 100000 h without maintenance
mounting location in cabinet
input type phase to phase, insensitive to phase rotation polarity, insensitive to CT polarity, phase to neutral, current input CT...X/5 A and X/1 A
settings operating mode manual, automatic
current of common 10 A