Schneider Electric

VigiPact Earth-leakage relay RH99M with manual reset - 0.03..30 A - 0..4.5 s - 240 V - 56173

Out of stock
SKU
56173
56%
Special Price Rp 4.035.986 Regular Price Rp 9.172.696
Details

RH99M is a DIN rail mounting residual current protection relay.

It protects against people direct or indirect contact, property fire hazards and motors.

It measures the earth leakage current in an electrical installation via its associated toroid.

It trips the associated circuit breaker when the set residual operation current is overrun.

The operational supply voltage is from 220 VAC to 240 VAC 50/60Hz.

The current sensitivity is selectable with 9 thresholds from 30 mA to 30 A.

The time delay is selectable with 9 settings from instantaneous to 4.5s.

It requires a local manual reset after a fault clearance.

The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz.

It is installed on a DIN-rail inside a switchboard and the protection degree is IP40.

It must be associated with a compatible Schneider Electric toroid.

More Information
More Information
Attribute Value
SKU 56173
relative humidity 95-95 % at 55-55 °C
ambient air temperature for storage -55-85 °C
overvoltage category IV
pollution degree 3 conforming to IEC 60664-1
ambient air temperature for operation -35-70 °C
reset manual reset
electrical shock protection class class II
range of product Vigirex
product or component type MCCB
net weight 0.3 kg
device short name RH99M
range Vigirex RH
wire stripping length auxiliary power supply: 7 mm for top connection, fault: 8 mm for bottom connection, relay test and fault reset: 5 mm for bottom connection, sensor: 5 mm for top connection, voltage presence: 8 mm for bottom connection
range compatibility TOA earth leakage current sensor, A earth leakage current sensor, L earth leakage current sensor
IK degree of protection IK07 conforming to EN 50102
mechanical robustness fire resistance conforming to IEC 60695-2-1, IK protection 2 joules: IK07 conforming to EN 50102, vibrations 13.2...100 Hz: 0.7 g, vibrations 2...13.2 Hz: +/- 1 mm
[Us] rated supply voltage 220...240 V AC 50/60 Hz 55...110 %
electromagnetic compatibility conducted and radiated emissions: , B, conforming to CISPR 11, conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6, electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2, high-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5, low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4, radiated susceptibility: , 3, conforming to IEC 61000-4-3
type of measurement earth fault current internal measurement, range: 80...100 %
earth-leakage protection class class A, class AC
relay application protection relay
test function local, remote test
monitoring electronics (continuous), power supply (continuous), relay/sensor link (continuous)
connections - terminals auxiliary power supply: terminal block cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12, auxiliary power supply: terminal block cable(s) 0.2-2.5 mm² rigid AWG 24...AWG 12, auxiliary power supply: terminal block cable(s) 0.25-2.5 mm² flexible AWG 24...AWG 12, fault: screw terminal cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12, fault: screw terminal cable(s) 0.2-4 mm² rigid AWG 24...AWG 12, fault: screw terminal cable(s) 0.25-2.5 mm² flexible AWG 24...AWG 12, relay test and fault reset: screw terminal cable(s) 0.14-1 mm² flexible AWG 26...AWG 16, relay test and fault reset: screw terminal cable(s) 0.14-1.5 mm² rigid AWG 26...AWG 16, relay test and fault reset: screw terminal cable(s) 0.25-0.5 mm² flexible AWG 26...AWG 16, sensor: screw terminal cable(s) 0.14-1 mm² flexible AWG 26...AWG 16, sensor: screw terminal cable(s) 0.14-1.5 mm² rigid AWG 26...AWG 16, sensor: screw terminal cable(s) 0.25-0.5 mm² flexible AWG 26...AWG 16, voltage presence: screw terminal cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12, voltage presence: screw terminal cable(s) 0.2-4 mm² rigid AWG 24...AWG 12, voltage presence: screw terminal cable(s) 0.25-2.5 mm² flexible AWG 24...AWG 12
height 81 mm
mounting support DIN rail
compatibility code RH99M
width 54 mm
depth 74 mm
IP degree of protection IP40 on front face: conforming to EN/IEC 60529, IP30 on side parts: conforming to EN/IEC 60529, IP20 on connection terminals: conforming to EN/IEC 60529
9 mm pitches 6
tightening torque auxiliary power supply: 0.6-0.6 N.m top, fault: 0.6-0.6 N.m bottom, relay test and fault reset: 0.25-0.25 N.m bottom, sensor: 0.25-0.25 N.m top, voltage presence: 0.6-0.6 N.m bottom
earthing system TT, TN-S, IT
[Ithe] conventional enclosed thermal current 8 A
minimum load 10 mA at 12 V
tamperproof of settings protected by sealable cover
type of setting selector
power consumption in VA 4 VA
network rated voltage 1000-1000 V - AC at 50/60 Hz (maximum), 1000-1000 V - AC at 400 Hz (maximum)
residual earth-leakage sensitity adjustment type adjustable 9 settings
residual earth-leakage time delay adjustment type instantaneous for 0.03-0.03 A, adjustable 9 settings 0-4.5 s for 0.03-30 A
earth leakage current 0.03-30 A
PT. Telesindo Citra Sejahtera © 2025 All Rights Reserved.