Schneider Electric

Zelio Logic analogue I/O extension module - 4 I O - 24 V DC - for Zelio Logic - SR3XT43BD

Out of stock
SKU
SR3XT43BD
45%
Special Price Rp 1.980.523 Regular Price Rp 3.600.951
Details

This product is part of the Zelio Logic range, an offer of smart relays for simple automation systems from 10 to 40 I/Os.

The analogue I/O extension module provides 2 input/outputs.

It is an extension module with an analogue output range of 0 to 10V and a maximum load current of 10mA for analogue output.

It provides 10bit on the input range and 10bit on the output range.

The temperature probe is Pt 100, 3-wire conforming to IEC 751.

It is furnished with screw terminal for electrical connections.

It is an IP20 and IP40 rated product.

It weighs 0.11kg.

This product meets EN/IEC 61000-4-12, EN/IEC 61000-4-5, EN/IEC 61000-4-3, EN/IEC 61000-4-4 level 3, EN/IEC 61000-4-6 level 3, EN/IEC 61000-4-2 level 3, EN/IEC 60068-2-6 Fc, EN/IEC 61000-4-11 and EN/IEC 60068-2-27 Ea standards.

Simple to select, install and program, Zelio Logic is suitable for all your applications.

Flexible, it offers you the choice of 2 ranges, compact or modular, extendable and 2 programming languages (FBD or LADDER).

Easy to use, Zelio Logic provides a real alternative to solutions based on cabled logic or specific cards.

More Information
More Information
Attribute Value
SKU SR3XT43BD
product certifications GOST, CSA, UL, C-Tick
relative humidity 95-95 % without condensation or dripping water
ambient air temperature for storage -40-70 °C
pollution degree 2 conforming to EN/IEC 61131-2
ambient air temperature for operation -20-55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2, -20-40 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
environmental characteristic EMC directive conforming to EN/IEC 61000-6-2, EMC directive conforming to EN/IEC 61000-6-3, EMC directive conforming to EN/IEC 61000-6-4, EMC directive conforming to EN/IEC 61131-2 zone B, low voltage directive conforming to EN/IEC 61131-2
range of product Zelio Logic
product or component type Relay & Power Supply
net weight 0.11 kg
standards EN/IEC 61000-4-12, EN/IEC 61000-4-4 level 3, EN/IEC 61000-4-6 level 3, EN/IEC 61000-4-3, EN/IEC 61000-4-2 level 3, EN/IEC 61000-4-5, EN/IEC 61000-4-11, EN/IEC 60068-2-6 Fc, EN/IEC 60068-2-27 Ea
range Smart Relay
analogue input type common mode
short-circuit protection with analogue output
repeat accuracy < +/- 0.3 °C, input range: - 25...125 °C at 25 °C for analogue input circuit, <= +/- 1 %, input range: 0...10 V at 25 °C for analogue input circuit, <= +/- 1 %, input range: 0...10 V at 55 °C for analogue output, <= +/- 1 %, input range: 0...20 mA at 25 °C for analogue input circuit
analogue output number 2
analogue input range 0...10 V, 0...20 mA, -25...125 °C
conversion error +/- 1 % of the full scale value, input range: 0...10 V (25 °C) for analogue output, +/- 1 % of the full scale value, input range: 0...10 V (55 °C) for analogue output, +/- 1 %, input range: 0...10 V (25 °C) for analogue input circuit, +/- 1 %, input range: 0...10 V (55 °C) for analogue input circuit, +/- 1 %, input range: 0...20 mA (25 °C) for analogue input circuit, +/- 1 %, input range: 0...20 mA (55 °C) for analogue input circuit, +/- 1.5 °C, input range: - 25...125 °C (25 °C) for analogue input circuit, +/- 1.5 °C, input range: - 25...125 °C (55 °C) for analogue input circuit
conversion time smart relay cycle time for analogue input circuit, smart relay cycle time for analogue output
operating distance 10 m with screened cable for analogue input circuit, 10 m with screened cable for analogue output
analogue input resolution 10 bits on the input range
reverse polarity protection analogue input circuit: with
maximum load current 10 mA for analogue output
analogue output range 0...10 V
connections - terminals screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end, screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end, screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) semi-solid, screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) solid, screw terminals, 2 x 0.25...2 x 1.5 mm² (AWG 23...AWG 16) solid
operating altitude 2000 m
IP degree of protection IP20 (terminal block) conforming to IEC 60529, IP40 (front panel) conforming to IEC 60529
tightening torque 0.5 N.m
load type resistive load for analogue output
analogue input number 2
maximum permissible voltage 30 V for analogue input circuit
[Imp] maximum permanent current 30 mA for analogue input circuit
input impedance 18 kOhm, input range: 0...10 V for analogue input circuit, 247 Ohm, input range: 0...20 mA for analogue input circuit
disturbance radiated/conducted class B conforming to EN 55022-11 group 1
maximum altitude transport 3048 m
LSB value 0.15 °C, - 25...125 °C for analogue input circuit, 20 µA, 0...20 mA for analogue input circuit, 9.8 mV, 0...10 V for analogue input circuit, 9.8 mV, 0...10 V for analogue output
analogue output resolution 10 bits on the output range
temperature probe type Pt 100, 3-wire conforming to IEC 751