Zelio Logic compact smart relay - 20 I O - 100..240 V AC - clock - display - SR2B201FU
This product is part of the Zelio Logic range, an offer of smart relays for simple automation systems from 10 to 40 I/Os.
The compact smart relay provides a real alternative to solutions based on cabled logic or specific cards.
It comes with display and clock.
Checks program memory on each power up and 0 to 240 with ladder programming number or control scheme lines.
Easy to use, Zelio Logic provides a real alternative to solutions based on cabled logic or specific cards It offers 8 relay outputs with normally opened contact and 12 discrete inputs.
It has a rated supply voltage of 100V to 240V AC, a maximum supply current of 50mA at 240V (without extension), 100mA at 100V (without extension) and a power consumption of 11VA without extension.
It is an IP20 and IP40 rated product.
It weighs 0.38kg.
This product meets EN/IEC 61000-4-6 level 3, EN/IEC 61000-4-11, EN/IEC 60068-2-27 Ea, EN/IEC 61000-4-5, EN/IEC 60068-2-6 Fc, EN/IEC 61000-4-12, EN/IEC 61000-4-2 level 3, EN/IEC 61000-4-3 and EN/IEC 61000-4-4 level 3 standards.
Simple to select, install and program, Zelio Logic is suitable for all your applications.
Flexible, it offers you the choice of 2 ranges, compact or modular, extendable and 2 programming languages (FBD or LADDER).
Easy to use, Zelio Logic provides a real alternative to solutions based on cabled logic or specific cards.
Attribute | Value |
---|---|
SKU | SR2B201FU |
product certifications | GL, GOST, CSA, UL, C-Tick |
relative humidity | 95-95 % without condensation or dripping water |
ambient air temperature for storage | -40-70 °C |
overvoltage category | III conforming to EN/IEC 60664-1 |
pollution degree | 2 conforming to EN/IEC 61131-2 |
ambient air temperature for operation | -20-40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2, -20-55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2 |
environmental characteristic | EMC directive conforming to EN/IEC 61000-6-2, EMC directive conforming to EN/IEC 61000-6-3, EMC directive conforming to EN/IEC 61000-6-4, EMC directive conforming to EN/IEC 61131-2 zone B, low voltage directive conforming to EN/IEC 61131-2 |
current state 1 guaranteed | >= 0.17 mA (discrete input) |
voltage state 1 guaranteed | >= 79 V for discrete input |
cycle time | 6-90 ms |
range of product | Zelio Logic |
product or component type | Relay & Power Supply |
net weight | 0.38 kg |
standards | EN/IEC 61000-4-12, EN/IEC 61000-4-4 level 3, EN/IEC 61000-4-6 level 3, EN/IEC 61000-4-3, EN/IEC 61000-4-2 level 3, EN/IEC 61000-4-5, EN/IEC 61000-4-11, EN/IEC 60068-2-6 Fc, EN/IEC 60068-2-27 Ea |
mechanical durability | 10000000 cycles for relay output |
range | Smart Relay |
[Us] rated supply voltage | 100...240 V AC |
immunity to microbreaks | 1 ms |
backup time | 10 years at 25 °C |
voltage state 0 guaranteed | <= 40 V for discrete input |
connections - terminals | screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid, screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid, screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end, screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid, screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end |
output voltage limits | 5...30 V DC (relay output), 24...250 V AC |
operating altitude | 2000 m |
IP degree of protection | IP20 (terminal block) conforming to IEC 60529, IP40 (front panel) conforming to IEC 60529 |
tightening torque | 0.5 N.m |
electrical durability | AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1, AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1, DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1, DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1 |
response time | 50 ms with ladder programming (from state 0 to state 1) for discrete input, 50 ms with ladder programming (from state 1 to state 0) for discrete input, 50...255 ms with FBD programming (from state 0 to state 1) for discrete input, 50...255 ms with FBD programming (from state 1 to state 0) for discrete input, 10 ms (from state 0 to state 1) for relay output, 5 ms (from state 1 to state 0) for relay output |
protection type | against inversion of terminals (control instructions not executed) |
supply frequency | 50/60 Hz |
contacts type and composition | NO for relay output |
supply voltage limits | 85-264 V |
number of outputs | 8 relay |
discrete input voltage | 100...240 V AC |
discrete input number | 12 |
input impedance | 350 kOhm for discrete input |
disturbance radiated/conducted | class B conforming to EN 55022-11 group 1 |
discrete input frequency | 57...63 Hz, 47...53 Hz |
output thermal current | 8 A for all 8 outputs for relay output |
number or control scheme lines | 0-500 with FBD programming, 0-240 with ladder programming |
clock drift | 12 min/year at 0-55 °C, 6 s/month at 25-25 °C |
power consumption in VA | 11 VA without extension |
discrete input current | 0.6 mA |
clock | with |
local display | with |
current state 0 guaranteed | <= 0.5 mA (discrete input) |
maximum supply current | 100 mA at 100 V (without extension), 50 mA at 240 V (without extension) |
isolation voltage | 1780 V |
switching capacity in mA | >= 10 mA at 12 V (relay output) |
operating rate in Hz | 0.1 Hz (at Ie) for relay output, 10 Hz (no load) for relay output |
maximum altitude transport | 3048 m |
checks | program memory on each power up |