Schneider Electric

Zelio Logic discrete I/O extension module - 10 I O - 100..240 V AC - for Zelio Logic - SR3XT101FU

Out of stock
SKU
SR3XT101FU
45%
Special Price Rp 835.652 Regular Price Rp 1.519.368
Details

This product is part of the Zelio Logic range, an offer of smart relays for simple automation systems from 10 to 40 I/Os.

The discrete I/O extension module provides 6 inputs and 4 relay outputs.

It is an extension module with a rated supply voltage of 100 to 240V AC and a discrete input current of 0.6mA.

It offers normally opened contacts for relay output, checks program memory on each power up and 120 with ladder programming number or control scheme lines.

It is furnished with screw terminal for electrical connections.

It offers long mechanical life, the mechanical durability is about 10 million cycles for relay output and 10 years of backup time at 25°C.

It is an IP20 and IP40 rated product.

It weighs 0.2kg.

This product meets EN/IEC 60068-2-27 Ea, EN/IEC 61000-4-12, EN/IEC 61000-4-3, EN/IEC 61000-4-2 level 3, EN/IEC 61000-4-5, EN/IEC 61000-4-6 level 3, EN/IEC 60068-2-6 Fc, EN/IEC 61000-4-11 and EN/IEC 61000-4-4 level 3 standards.

Simple to select, install and program, Zelio Logic is suitable for all your applications.

Flexible, it offers you the choice of 2 ranges, compact or modular, extendable and 2 programming languages (FBD or LADDER).

Easy to use, Zelio Logic provides a real alternative to solutions based on cabled logic or specific cards.

More Information
More Information
Attribute Value
SKU SR3XT101FU
product certifications GL, GOST, CSA, UL, C-Tick
relative humidity 95-95 % without condensation or dripping water
ambient air temperature for storage -40-70 °C
overvoltage category III conforming to EN/IEC 60664-1
pollution degree 2 conforming to EN/IEC 61131-2
ambient air temperature for operation -20-40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2, -20-55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
environmental characteristic EMC directive conforming to EN/IEC 61000-6-2, EMC directive conforming to EN/IEC 61000-6-3, EMC directive conforming to EN/IEC 61000-6-4, EMC directive conforming to EN/IEC 61131-2 zone B, low voltage directive conforming to EN/IEC 61131-2
current state 1 guaranteed >= 0.17 mA (discrete input)
voltage state 1 guaranteed >= 79 V for discrete input
cycle time 6-90 ms
range of product Zelio Logic
product or component type Relay & Power Supply
net weight 0.2 kg
standards EN/IEC 61000-4-12, EN/IEC 61000-4-4 level 3, EN/IEC 61000-4-6 level 3, EN/IEC 61000-4-3, EN/IEC 61000-4-2 level 3, EN/IEC 61000-4-5, EN/IEC 61000-4-11, EN/IEC 60068-2-6 Fc, EN/IEC 60068-2-27 Ea
mechanical durability 10000000 cycles for relay output
range Smart Relay
[Us] rated supply voltage 100...240 V AC
backup time 10 years at 25 °C
voltage state 0 guaranteed <= 40 V for discrete input
reverse polarity protection with
connections - terminals screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid, screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid, screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end, screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid, screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end
output voltage limits 5...30 V DC (relay output), 24...250 V AC
operating altitude 2000 m
IP degree of protection IP20 (terminal block) conforming to IEC 60529, IP40 (front panel) conforming to IEC 60529
tightening torque 0.5 N.m
electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1, AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1, DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1, DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
response time 50 ms with ladder programming (from state 0 to state 1) for discrete input, 50 ms with ladder programming (from state 1 to state 0) for discrete input, 50...255 ms with FBD programming (from state 0 to state 1) for discrete input, 50...255 ms with FBD programming (from state 1 to state 0) for discrete input, 10 ms (from state 0 to state 1) for relay output, 5 ms (from state 1 to state 0) for relay output
supply frequency 50/60 Hz
contacts type and composition NO for relay output
supply voltage limits 85-264 V
number of outputs 4 relay
discrete input voltage 100...240 V AC
discrete input number 6
input impedance 350 kOhm for discrete input
disturbance radiated/conducted class B conforming to EN 55022-11 group 1
discrete input frequency 57...63 Hz, 47...53 Hz
output thermal current 8 A for all 4 outputs for relay output
number or control scheme lines 120-120 with ladder programming
clock drift 12 min/year at 0-55 °C
discrete input current 0.6 mA
current state 0 guaranteed <= 0.5 mA (discrete input)
switching capacity in mA >= 10 mA at 12 V (relay output)
operating rate in Hz 0.1 Hz (at Ie) for relay output, 10 Hz (no load) for relay output
maximum altitude transport 3048 m
checks program memory on each power up