Schneider Electric

Zelio Logic modular smart relay Zelio Logic - 10 I O - 100..240 V AC - clock - display - SR3B101FU

Out of stock
SKU
SR3B101FU
45%
Special Price Rp 1.701.769 Regular Price Rp 3.094.125
Details

This Zelio Logic SR3 compact smart relay / programmable controller uses a supply voltage of 100V-240V alternating current.

It has 10 inputs / outputs with screw-clamp terminals.

It has compact design, allowing installation on DIN rail.

It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons.

Its simple ladder programming makes it adapted for non-specialists.

More Information
More Information
Attribute Value
SKU SR3B101FU
product certifications GL, GOST, CSA, UL, C-Tick
relative humidity 95-95 % without condensation or dripping water
ambient air temperature for storage -40-70 °C
overvoltage category III conforming to EN/IEC 60664-1
pollution degree 2 conforming to EN/IEC 61131-2
ambient air temperature for operation -20-40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2, -20-55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
environmental characteristic EMC directive conforming to EN/IEC 61000-6-2, EMC directive conforming to EN/IEC 61000-6-3, EMC directive conforming to EN/IEC 61000-6-4, EMC directive conforming to EN/IEC 61131-2 zone B, low voltage directive conforming to EN/IEC 61131-2
current state 1 guaranteed >= 0.17 mA (discrete input)
voltage state 1 guaranteed >= 79 V for discrete input
cycle time 6-90 ms
range of product Zelio Logic
product or component type Relay & Power Supply
net weight 0.25 kg
standards EN/IEC 61000-4-12, EN/IEC 61000-4-4 level 3, EN/IEC 61000-4-6 level 3, EN/IEC 61000-4-3, EN/IEC 61000-4-2 level 3, EN/IEC 61000-4-5, EN/IEC 61000-4-11, EN/IEC 60068-2-6 Fc, EN/IEC 60068-2-27 Ea
mechanical durability 10000000 cycles for relay output
range Smart Relay
[Us] rated supply voltage 100...240 V
immunity to microbreaks 10 ms
backup time 10 years at 25 °C
voltage state 0 guaranteed <= 40 V for discrete input
connections - terminals screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid, screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid, screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end, screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid, screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end
output voltage limits 5...30 V DC (relay output), 24...250 V AC
operating altitude 2000 m
IP degree of protection IP20 (terminal block) conforming to IEC 60529, IP40 (front panel) conforming to IEC 60529
tightening torque 0.5 N.m
electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1, AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1, DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1, DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
response time 50 ms with ladder programming (from state 0 to state 1) for discrete input, 50 ms with ladder programming (from state 1 to state 0) for discrete input, 50...255 ms with FBD programming (from state 0 to state 1) for discrete input, 50...255 ms with FBD programming (from state 1 to state 0) for discrete input, 10 ms (from state 0 to state 1) for relay output, 5 ms (from state 1 to state 0) for relay output
protection type against inversion of terminals (control instructions not executed)
supply frequency 50/60 Hz
contacts type and composition NO for relay output
supply voltage limits 85-264 V
number of outputs 4 relay
discrete input voltage 100...240 V AC
discrete input number 6
input impedance 350 kOhm for discrete input
disturbance radiated/conducted class B conforming to EN 55022-11 group 1
discrete input frequency 57...63 Hz, 47...53 Hz
output thermal current 8 A for all 4 outputs for relay output
number or control scheme lines 0-500 with FBD programming, 0-240 with ladder programming
clock drift 12 min/year at 0-55 °C, 6 s/month at 25-25 °C
power consumption in VA 12 VA with extensions, 7 VA without extension
discrete input current 0.6 mA
clock with
local display with
current state 0 guaranteed <= 0.5 mA (discrete input)
maximum supply current 30 mA at 240 V (without extension), 40 mA at 240 V (with extensions), 80 mA at 100 V (with extensions), 80 mA at 100 V (without extension)
isolation voltage 1780 V
switching capacity in mA >= 10 mA at 12 V (relay output)
operating rate in Hz 0.1 Hz (at Ie) for relay output, 10 Hz (no load) for relay output
maximum altitude transport 3048 m
checks program memory on each power up
PT. Telesindo Citra Sejahtera © 2025 All Rights Reserved.