Attribute Value
SKU SR3PACK2FU
product certifications GL, GOST, CSA, UL, C-Tick
relative humidity 95-95 % without condensation or dripping water
ambient air temperature for storage -40-70 °C
overvoltage category III conforming to EN/IEC 60664-1
pollution degree 2 conforming to EN/IEC 61131-2
ambient air temperature for operation -20-40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2, -20-55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
environmental characteristic EMC directive conforming to EN/IEC 61000-6-2, EMC directive conforming to EN/IEC 61000-6-3, EMC directive conforming to EN/IEC 61000-6-4, EMC directive conforming to EN/IEC 61131-2 zone B, low voltage directive conforming to EN/IEC 61131-2
current state 1 guaranteed >= 0.17 mA (discrete input)
voltage state 1 guaranteed >= 79 V for discrete input
cycle time 6-90 ms
range of product Zelio Logic
product or component type Relay & Power Supply
net weight 0.85 kg
standards EN/IEC 61000-4-12, EN/IEC 61000-4-4 level 3, EN/IEC 61000-4-6 level 3, EN/IEC 61000-4-3, EN/IEC 61000-4-2 level 3, EN/IEC 61000-4-5, EN/IEC 61000-4-11, EN/IEC 60068-2-6 Fc, EN/IEC 60068-2-27 Ea
mechanical durability 10000000 cycles for relay output
range Smart Relay
[Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
[Us] rated supply voltage 100...240 V
immunity to microbreaks 10 ms
backup time 10 years at 25 °C
voltage state 0 guaranteed <= 40 V for discrete input
input/output number 26
connections - terminals screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid, screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid, screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end, screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid, screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end
output voltage limits 5...30 V DC (relay output), 24...250 V AC
operating altitude 2000 m
IP degree of protection IP20 (terminal block) conforming to IEC 60529, IP40 (front panel) conforming to IEC 60529
tightening torque 0.5 N.m
electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1, AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1, DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1, DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
response time 50 ms with ladder programming (from state 0 to state 1) for discrete input, 50 ms with ladder programming (from state 1 to state 0) for discrete input, 50...255 ms with FBD programming (from state 0 to state 1) for discrete input, 50...255 ms with FBD programming (from state 1 to state 0) for discrete input, 10 ms (from state 0 to state 1) for relay output, 5 ms (from state 1 to state 0) for relay output
protection type against inversion of terminals (control instructions not executed)
supply frequency 50/60 Hz
contacts type and composition NO for relay output
kit composition Zelio Soft 2 programming software CD-ROM, cable PC SR2USB01 for connection to PC, SR3B261FU
supply voltage limits 85-264 V
number of outputs 10 relay
discrete input voltage 100...240 V AC
discrete input number 16
input impedance 350 kOhm for discrete input
disturbance radiated/conducted class B conforming to EN 55022-11 group 1
discrete input frequency 57...63 Hz, 47...53 Hz
output thermal current 5 A for 2 outputs for relay output, 8 A for 8 outputs for relay output
number or control scheme lines 120-120 with ladder programming, 0-200 with FBD programming
clock drift 12 min/year at 0-55 °C, 6 s/month at 25-25 °C
power consumption in VA 12 VA without extension, 17 VA with extensions
discrete input current 0.6 mA
clock with
local display with
current state 0 guaranteed <= 0.5 mA (discrete input)
maximum supply current 80 mA at 100 V (with extensions), 100 mA at 100 V (without extension), 50 mA at 240 V (without extension), 60 mA at 240 V (with extensions)
isolation voltage 1780 V
switching capacity in mA >= 10 mA at 12 V (relay output)
operating rate in Hz 0.1 Hz (at Ie) for relay output, 10 Hz (no load) for relay output
maximum altitude transport 3048 m
checks program memory on each power up