Schneider Electric
Zelio Logic modular smart relay Zelio Logic - “discovery†pack - 26 I O - 100..240 V AC - SR3PACK2FU
Out of stock
SKU
SR3PACK2FU
Details
This Zelio Logic SR3 discovery pack compact smart relay / programmable controller uses a supply voltage of 100V to 240V alternating current.
It has 26 inputs / outputs with screw-clamp terminals and has an integrated LCD display.
It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons.
This discovery package includes one copy of Zelio Soft and one USB cable to connect the relay to your PC.
Its simple ladder programming makes it adapted for non-specialists.
More Information
Attribute | Value |
---|---|
SKU | SR3PACK2FU |
product certifications | GL, GOST, CSA, UL, C-Tick |
relative humidity | 95-95 % without condensation or dripping water |
ambient air temperature for storage | -40-70 °C |
overvoltage category | III conforming to EN/IEC 60664-1 |
pollution degree | 2 conforming to EN/IEC 61131-2 |
ambient air temperature for operation | -20-40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2, -20-55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2 |
environmental characteristic | EMC directive conforming to EN/IEC 61000-6-2, EMC directive conforming to EN/IEC 61000-6-3, EMC directive conforming to EN/IEC 61000-6-4, EMC directive conforming to EN/IEC 61131-2 zone B, low voltage directive conforming to EN/IEC 61131-2 |
current state 1 guaranteed | >= 0.17 mA (discrete input) |
voltage state 1 guaranteed | >= 79 V for discrete input |
cycle time | 6-90 ms |
range of product | Zelio Logic |
product or component type | Relay & Power Supply |
net weight | 0.85 kg |
standards | EN/IEC 61000-4-12, EN/IEC 61000-4-4 level 3, EN/IEC 61000-4-6 level 3, EN/IEC 61000-4-3, EN/IEC 61000-4-2 level 3, EN/IEC 61000-4-5, EN/IEC 61000-4-11, EN/IEC 60068-2-6 Fc, EN/IEC 60068-2-27 Ea |
mechanical durability | 10000000 cycles for relay output |
range | Smart Relay |
[Uimp] rated impulse withstand voltage | 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 |
[Us] rated supply voltage | 100...240 V |
immunity to microbreaks | 10 ms |
backup time | 10 years at 25 °C |
voltage state 0 guaranteed | <= 40 V for discrete input |
input/output number | 26 |
connections - terminals | screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid, screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid, screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end, screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid, screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end |
output voltage limits | 5...30 V DC (relay output), 24...250 V AC |
operating altitude | 2000 m |
IP degree of protection | IP20 (terminal block) conforming to IEC 60529, IP40 (front panel) conforming to IEC 60529 |
tightening torque | 0.5 N.m |
electrical durability | AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1, AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1, DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1, DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1 |
response time | 50 ms with ladder programming (from state 0 to state 1) for discrete input, 50 ms with ladder programming (from state 1 to state 0) for discrete input, 50...255 ms with FBD programming (from state 0 to state 1) for discrete input, 50...255 ms with FBD programming (from state 1 to state 0) for discrete input, 10 ms (from state 0 to state 1) for relay output, 5 ms (from state 1 to state 0) for relay output |
protection type | against inversion of terminals (control instructions not executed) |
supply frequency | 50/60 Hz |
contacts type and composition | NO for relay output |
kit composition | Zelio Soft 2 programming software CD-ROM, cable PC SR2USB01 for connection to PC, SR3B261FU |
supply voltage limits | 85-264 V |
number of outputs | 10 relay |
discrete input voltage | 100...240 V AC |
discrete input number | 16 |
input impedance | 350 kOhm for discrete input |
disturbance radiated/conducted | class B conforming to EN 55022-11 group 1 |
discrete input frequency | 57...63 Hz, 47...53 Hz |
output thermal current | 5 A for 2 outputs for relay output, 8 A for 8 outputs for relay output |
number or control scheme lines | 120-120 with ladder programming, 0-200 with FBD programming |
clock drift | 12 min/year at 0-55 °C, 6 s/month at 25-25 °C |
power consumption in VA | 12 VA without extension, 17 VA with extensions |
discrete input current | 0.6 mA |
clock | with |
local display | with |
current state 0 guaranteed | <= 0.5 mA (discrete input) |
maximum supply current | 80 mA at 100 V (with extensions), 100 mA at 100 V (without extension), 50 mA at 240 V (without extension), 60 mA at 240 V (with extensions) |
isolation voltage | 1780 V |
switching capacity in mA | >= 10 mA at 12 V (relay output) |
operating rate in Hz | 0.1 Hz (at Ie) for relay output, 10 Hz (no load) for relay output |
maximum altitude transport | 3048 m |
checks | program memory on each power up |
Technical Documents