Schneider Electric
Zelio Time time delay relay 10 functions - 1 s..100 h - 24..240 V AC - 1 OC - RE17RMMU
In stock
SKU
RE17RMMU
Details
This Zelio RE17R timing relay can be set between 0.1 seconds and 100 hours, has an output rating of 8A, is 17.5mm wide and can be supplied with 24V DC, 24V to 240V AC.
It also has 1 changeover contact SPDT (single pole double throw).
It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device.
It also offers a sealable cover, simple and precise settings with rotary trimmers.
multi function timer for a simple integration in hard-wired logic schematics: ideal for refurbishment of old installations without using a PLC.
More Information
Attribute | Value |
---|---|
SKU | RE17RMMU |
product certifications | GL, CSA, cULus |
relative humidity | 93-93 % without condensation conforming to IEC 60068-2-30 |
ambient air temperature for storage | -30-60 °C |
ambient air temperature for operation | -20-60 °C |
safety reliability data | MTTFd = 296.8 years, B10d = 270000 |
nominal output current | 8 A |
housing material | self-extinguishing |
maximum delay response | 100 ms |
input voltage | 10 V |
range of product | Zelio Time |
product or component type | Relay & Power Supply |
net weight | 0.07 kg |
standards | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, 2006/95/EC, 2004/108/EC, IEC 61812-1 |
mechanical durability | 10000000 cycles |
device short name | RE17R |
breaking capacity | 2000 VA |
range | Timer Relay |
[Uimp] rated impulse withstand voltage | 5 kV during 1.2/50 µs |
contacts material | cadmium free |
minimum switching current | 10 mA at 5 V DC |
insulation resistance | 100 MOhm at 500 V DC conforming to IEC 60664-1 |
[Us] rated supply voltage | 24 V DC, 24...240 V AC 50/60 Hz |
electromagnetic compatibility | electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2, electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2, susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3, electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4, electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4, 1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5, 1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5, conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6, voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11, voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11, conducted and radiated emissions: , class B, conforming to EN 55022 |
mounting position | any position in relation to normal vertical mounting plane |
immunity to microbreaks | 20 ms |
repeat accuracy | +/- 0.5 % conforming to IEC 61812-1 |
discrete output type | relay |
functionality | multifunction |
setting accuracy of time delay | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 |
connections - terminals | screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end, screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end, screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end, screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end |
height | 90 mm |
mounting support | 35 mm DIN rail conforming to EN/IEC 60715 |
compatibility code | RE17 |
marking | CE |
width | 17.5 mm |
depth | 72 mm |
vibration resistance | 20 m/s² (f= 10-150 Hz) conforming to IEC 60068-2-6 |
dielectric strength | 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1 |
IP degree of protection | IP20 (terminal block) conforming to IEC 60529, IP40 (housing) conforming to IEC 60529, IP50 (front panel) conforming to IEC 60529 |
tightening torque | 0.6-1 N.m conforming to IEC 60947-1 |
electrical durability | 100000 cycles (8 A at 250 V AC maximum) for resistive load |
control type | selector switch front panel |
local signalling | LED indicator for on steady: relay energised, no timing in progress, LED indicator for flashing: timing in progress 80 % ON and 20 % OFF, LED indicator for pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) 5 % ON and 95 % OFF |
supply frequency | 50...60 Hz +/- 5 % |
contacts type and composition | 1 C/O |
shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
reset time | 120 ms on de-energisation typical |
maximum switching voltage | 250 V AC |
time delay range | 1...10 min, 10...100 h, 0.1...1 s, 6...60 s, 6...60 min, 1...10 s, 1...10 h |
maximum power consumption in W | 0.6 W at 24 V DC |
impulse duration | 100 ms with load in parallel typical, 30 ms typical |
time delay type | At, A, H, Ht, A, Ac, At, B, Bw, C, D, Di, H, Ht, C, B, D, Bw, Di, Ac |
maximum switching current | 8 A AC/DC |
power consumption in VA | 0-32 VA at 240 V AC |
operating rate in Hz | 10 Hz |
temperature drift | +/- 0.05 %/°C |
creepage distance | 4 kV/3 conforming to IEC 60664-1 |
voltage range | 0.85...1.1 Us |
voltage drift | +/- 0.2 %/V |
on-load factor | 100 % |
Technical Documents